1887
Volume 2014, Issue 1
  • ISSN: 2305-7823
  • E-ISSN:

ملخص

The introduction of transcatheter aortic valve implantation (TAVI) has resulted in a paradigm shift in the treatment of patients with severe aortic stenosis. Data from the recent U.S CoreValve Trial suggest, for the first time, that TAVI is associated with a significantly higher rate of survival at one year compared to surgical aortic valve replacement (SAVR) in the treatment of high-risk patients affected by severe aortic stenosis. The present review discusses this study and the current evidence about TAVI, for the treatment of severe aortic stenosis, from major trials and real world registries.

Loading

جارٍ تحميل قياسات المقالة...

/content/journals/10.5339/gcsp.2014.12
٢٠١٤-٠٧-٠١
٢٠٢٤-١٢-٣٠
Loading full text...

Full text loading...

/deliver/fulltext/gcsp/2014/1/gcsp.2014.12.html?itemId=/content/journals/10.5339/gcsp.2014.12&mimeType=html&fmt=ahah

References

  1. Cribier A, Eltchaninoff H, Bash A, Borenstein N, Tron C, Bauer F, Derumeaux G, Anselme F, Laborde F, Leon MB. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation 2002; 106:24:30063008.
    [Google الباحث العلمي]
  2. Smith CR, Leon MB, Mack MJ, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, Williams M, Dewey T, Kapadia S, Babaliaros V, Thourani VH, Corso P, Pichard AD, Bavaria JE, Herrmann HC, Akin JJ, Anderson WN, Wang D, Pocock SJ, PARTNER Trial Investigators . Transcatheter versus surgical aortic-valve replacement in high-risk patients. N Engl J Med. 2011; 364:23:21872198.
    [Google الباحث العلمي]
  3. Adams DH, Popma JJ, Reardon MJ, Yakubov SJ, Coselli JS, Deeb GM, Gleason TG, Buchbinder M, Hermiller J Jr, Kleiman NS, Chetcuti S, Heiser J, Merhi W, Zorn G, Tadros P, Robinson N, Petrossian G, Chad Hughes G, Kevin Harrison J, Conte J, Maini B, Mumtaz M, Chenoweth S, Oh JK, for the U.S. CoreValve Clinical Investigators . Transcatheter aortic-valve replacement with a self-expanding prosthesis. N Engl J Med. 2014; 370::17901798.
    [Google الباحث العلمي]
  4. Leon MB, Smith CR, Mack M, Miller DC, Moses JW, Svensson LG, Tuzcu EM, Webb JG, Fontana GP, Makkar RR, Brown DL, Block PC, Guyton RA, Pichard AD, Bavaria JE, Herrmann HC, Douglas PS, Petersen JL, Akin JJ, Anderson WN, Wang D, Pocock S, PARTNER Trial Investigators . Transcatheter aortic-valve implantation for aortic stenosis in patients who cannot undergo surgery. N Engl J Med. 2010; 363:17:15971607.
    [Google الباحث العلمي]
  5. Piazza N, Kalesan B, van Mieghem N, Head S, Wenaweser P, Carrel TP, Bleiziffer S, de Jaegere PP, Gahl B, Anderson RH, Kappetein AP, Lange R, Serruys PW, Windecker S, Jüni P. A 3-center comparison of 1-year mortality outcomes between transcatheter aortic valve implantation and surgical aortic valve replacement on the basis of propensity score matching among intermediate-risk surgical patients. JACC Cardiovasc Interv. 2013; 6:5:443451.
    [Google الباحث العلمي]
  6. Hamm CW, Möllmann H, Holzhey D, Beckmann A, Veit C, Figulla HR, Cremer J, Kuck KH, Lange R, Zahn R, Sack S, Schuler G, Walther T, Beyersdorf F, Böhm M, Heusch G, Funkat AK, Meinertz T, Neumann T, Papoutsis K, Schneider S, Welz A, Mohr FW, for the GARY-Executive Board . The German Aortic Valve Registry (GARY): in-hospital outcome. Eur Heart J. 2013 Sep 10;, [Epub ahead of print].
    [Google الباحث العلمي]
  7. Van Brabandt H, Neyt M, Hulstaert F. Transcatheter aortic valve implantation (TAVI): risky and costly. BMJ. 2012; 345::e4710.
    [Google الباحث العلمي]
  8. Petronio AS, De Carlo M, Bedogni F, Marzocchi A, Klugmann S, Maisano F, Ramondo A, Ussia GP, Ettori F, Poli A, Brambilla N, Saia F, De Marco F, Colombo A. Safety and efficacy of the subclavian approach for transcatheter aortic valve implantation with the corevalve revalving system. Circ Cardiovasc Interv. 2010; 3:4:359366.
    [Google الباحث العلمي]
  9. Hayashida K, Romano M, Lefèvre T, Chevalier B, Farge A, Hovasse T, Le Houerou D, Morice MC. The transaortic approach for transcatheter aortic valve implantation: a valid alternative to the transapical access in patients with no peripheral vascular option. A single center experience. Eur J Cardiothorac Surg. 2013; 44:4:692700.
    [Google الباحث العلمي]
  10. Di Mario C, Eltchaninoff H, Moat N, Goicolea J, Ussia GP, Kala P, Wenaweser P, Zembala M, Nickenig G, Alegria Barrero E, Snow T, Iung B, Zamorano P, Schuler G, Corti R, Alfieri O, Prendergast B, Ludman P, Windecker S, Sabate M, Gilard M, Witowski A, Danenberg H, Schroeder E, Romeo F, Macaya C, Derumeaux G, Maggioni A, Tavazzi L, Transcatheter Valve Treatment Sentinel Registry (TCVT) Investigators of the EURObservational Research Programme (EORP) of the European Society of Cardiology . The 2011-12 pilot European Sentinel Registry of Transcatheter Aortic Valve Implantation: in-hospital results in 4,571 patients. EuroIntervention 2013; 8:12:13621371.
    [Google الباحث العلمي]
  11. Gilard M, Eltchaninoff H, Iung B, Donzeau-Gouge P, Chevreul K, Fajadet J, Leprince P, Leguerrier A, Lievre M, Prat A, Teiger E, Lefevre T, Himbert D, Tchetche D, Carrié D, Albat B, Cribier A, Rioufol G, Sudre A, Blanchard D, Collet F, Dos Santos P, Meneveau N, Tirouvanziam A, Caussin C, Guyon P, Boschat J, Le Breton H, Collart F, Houel R, Delpine S, Souteyrand G, Favereau X, Ohlmann P, Doisy V, Grollier G, Gommeaux A, Claudel JP, Bourlon F, Bertrand B, Van Belle E, Laskar M, FRANCE 2 Investigators . Registry of transcatheter aortic-valve implantation in high-risk patients. N Engl J Med. 2012; 366:18:17051715.
    [Google الباحث العلمي]
  12. Chieffo A, Buchanan GL, Van Mieghem NM, Tchetche D, Dumonteil N, Latib A, van der Boon RM, Vahdat O, Marcheix B, Farah B, Serruys PW, Fajadet J, Carrié D, de Jaegere PP, Colombo A. Transcatheter aortic valve implantation with the Edwards SAPIEN versus the Medtronic CoreValve Revalving system devices: a multicenter collaborative study: the PRAGMATIC Plus Initiative (Pooled-RotterdAm-Milano-Toulouse In Collaboration). J Am Coll Cardiol. 2013; 61:8:830836.
    [Google الباحث العلمي]
  13. Blackman DJ, Baxter PD, Gale CP, Moat NE, MacCarthy PA, Hildick-Smith D, Trivedi U, Cunningham D, De Belder MA, Ludman PF, and on behalf of the National Institute for Cardiovascular Outcomes Research . Do Outcomes from Transcatheter Aortic Valve Implantation Vary According to Access Route and Valve Type? The UK TAVI Registry. J Interv Cardiol. 2013; 27:1:8695.
    [Google الباحث العلمي]
  14. Abdel-Wahab M, Mehilli J, Frerker C, Neumann F-J, Kurz T, Tölg R, Zachow D, Guerra E, Massberg S, Schäfer U, El-Mawardy M, Richardt G, CHOICE investigators . Comparison of balloon-expandable vs self-expandable valves in patients undergoing transcatheter aortic valve replacement: the CHOICE randomized clinical trial. JAMA 2014; 311:15:15031514.
    [Google الباحث العلمي]
  15. Leon MB, Piazza N, Nikolsky E, Blackstone EH, Cutlip DE, Kappetein AP, Krucoff MW, Mack M, Mehran R, Miller C, Morel MA, Petersen J, Popma JJ, Takkenberg JJ, Vahanian A, van Es GA, Vranckx P, Webb JG, Windecker S, Serruys PW. Standardized endpoint definitions for transcatheter aortic valve implantation clinical trials: a consensus report from the Valve Academic Research Consortium. Eur Heart J. 2011; 32:2:205217.
    [Google الباحث العلمي]
/content/journals/10.5339/gcsp.2014.12
Loading
/content/journals/10.5339/gcsp.2014.12
Loading

جارٍ تحميل البيانات والوسائط...

  • نوع المستند: Research Article
الموضوعات الرئيسية degenerative aortic valve stenosissurgical aortic valve replacementtranscatheter aortic valve implantation and U.S. CoreValve Trial
هذه الخانة مطلوبة
يُرجى إدخال عنوان بريد إلكتروني صالح
Approval was a Success
Invalid data
An Error Occurred
Approval was partially successful, following selected items could not be processed due to error